Home > Sell > copper-clad aluminum conductor

ACSR ASTM B232 aLUMINIUM CONDUCTORS STEEL REINFORCED

ACSR ASTM B232 aLUMINIUM CONDUCTORS STEEL REINFORCED
Click to see the original picture
Product Name:ACSR ASTM B232 aLUMINIUM CONDUCTORS STEEL REINFORCED
Place of Origin:Peoples Republic of China
Post Date:July 17, 2009
Edit Date:July 17, 2009
Company Name :
Detailed Product Description:
  • Conductor Material: Aluminum
  • Brand Name: SANHE
  • Application: Overhead
  • Place of Origin: Henan China (Mainland)
  • Model Number: ACSR

Aluminium Conductor Steel Reinforced ACSR wire ACSR conductor or ACSR bare conductor used as bare overhead transmission cable

Aluminium Conductor Steel Reinforced  ACSR wire ACSR conductor or ACSR bare conductorused used as bare overhead transmission cable and as primary and secondary distribution cable.

Applications


Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Construction


Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.

Specifications


ACSR bare conductor meets or exceeds the following ASTM specifications:

B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes

  • Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
  • Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq.ft sun, 0.5 coefficients of emissivity and absorption.

       

    Code NameCode NameCode NameCode NameHigh  Strength  Strandings
    Turkey IbisEgretCurlewGrouse
    SwanLarkFlamingoBluejayPetrel
    SwanatePelicanGannetFinchMinorca
    SparrowFlickerStiltBuntingLeghorn
    SparateHawkStarlingGrackleGuinea
    RobinHenRedwingBitternDotterel
    RavenOspreyTernPheasantDorking
    QuailParakeetCondorDipperCochin
    PigeonDoveCuckooMartinBrahma
    PenguinEagleDrakeBobolink
    WaxwingPeacockMallardPlover
    PartridgeSquabRuddyNuthatch
    OstrichWood DuckCanaryParrot
    LinnetTealRailLapwing
    OrioleKingbirdCardinalFalcon
    ChickadeeRookOrtlanChukar
    BrantGrosbeak


  • Related Products