- Model Number: TY-9600
- Place of Origin: Jiangsu, China (Mainland)
- Brand Name: JIEBO
- Brand Name: JIEBO
- Place of Origin: Jiangsu China (Mainland)
- Model Number: TY-9600
This apparatus is widely used in material analysis of various industries, such as iron and steel, non-ferrous metal, metallurgy
I. Application area
This apparatus is widely used in material analysis of various industries, such as iron and steel, non-ferrous metal, metallurgy, machinery, chemical equipment, quality inspection system and so on. It is also used in blast furnace analysis, routine identification and analysis in metallic smelt industry.
Manage blast furnace process control by various processes of blast furnace celerity analysis.
Identification of product specifications.
Material checking and acceptance.
Quality inspection.
II. Allocating and analyzing channel and quantitative work scale.
Major Features
The human oriented design, the standardized and modularized manufacture make the apparatus smaller.
The core components are all imported, which strengthen the stability and reliability of the apparatus.
We adopt the advanced foreign technologies of excitation source and design the excitation source of high energy, high stability by our own to fulfill the needs of ultrahigh content and trace analysis.
It adopts overall exit slit using technology which is convenient for choosing passage and regulating.
The high voltage of the PHT in the apparatus is controlled directly by computer and regulated by software, which improved efficiency of the passage.
In the apparatus, there is an automatic constant temperature system which solve the problem of bad effects to the optics system caused by changing temperature.
The multi-language operation software and flexible configuration enable the apparatus more humanistic.
This apparatus can analyze various kinds of matrix, such as Fe, Co, Ni, Ti, Cu, Al, Pb, Mg, Zn and Sn.
III. The configuration of the product
Direct Reading Spectrometer
The excitation source
The sparks excitation source of a high frequency of 400Hz has the capacity of pre sparks with high power.
Impulse scope: +15KV.
Room vacuum spectrometer
Analysis of the scope of band: 130-800nm.
1-meter focal length, Palau Xinglong Georgia installed holographic concave grating;
Partial constant temperature 30±0.1
Permitting 64 passages (the configuration standard is 10 passages).
Sparks excitation platform
An Argon-charge excitation workroom of minimal Argon consumption;
The sparks platform is convenient for replacing;
The sparks room is convenient for washing.
Measure system
Its major work is to inspect and record the spectrum signals and keep all the systems working normally.
Measuring pattern: Subsection integral and send the results to the computer.
PMT high voltage power supply stability: fluctuation rate < 0.5% /8h
PMT pressure adjustment program.
Data processing system
Hardware configuration (basic configuration)
Computer: PIV3.0G/80G/512M /17 LCD display
Printer: SMSUNG Laser printer
Software functions
Multi-languages operation software under WINDOWS operation system
Various samples calibrate one analysis result simultaneously
Polygon and polynomial curve fitting
The concentration base of drawing curve management
Matrix correction and disturbance correction
There is a power management module
Quality controlling standard and management
System condition inspection
Data outputting management
IV. Corollary Equipments (self-contained)
Argon system
Two cylinders of high purity argon gas. (The purity degree>99.996%)
One YQY-6 Oxygen reducing valve.
One argon gas purifier.
Power supply system
The air switch which has the function of blackout protector permits a highest current of 10A.
Electronic AC Power Supply≥3KV, single phase 220V
Independent exclusive Ground (the grounding copper ware: R<1Ω, length 2.5 m, diameter 35-50mm)
Sample making system
One sampling miller of double millstones whose diameter is 350mm. It suits for milling the iron and steel samples (non-ferrous metal samples had better be dealt with by small lathe, such as: Al, Cu, Pb and etc.)
One cutter
Standard samples
Analyzing different materials, choosing curve samples and controlling curves.
Environmental equipment
Install air conditioner according to the size of the place laid the apparatus.
Install dehumidifier in humid areas.
One small vacuum cleaner.
III. Apparatus installation
The apparatus installation should be carried out by the engineers of our company.
Check the goods and packing list to affirm that they are qualified and the contents match the instructions.
Check whether or not the lab is qualified for using the apparatus.
Install and start the apparatus to check if everything works well.
Test and adjust according to the requirements on the technical contract. Make sure that the apparatus complies with the requirements.
Train the users, including: operate apparatus, use software of the apparatus and daily maintenances of the apparatus.
IV. Equipment acceptance checking
Choose one or two sets of national standard samples appointed by both parties and check the equipment at the manufacturing site by using standard samples. Check and analyze the precision with repeated acceptance checking program and fill the installation and acceptance checking report.
V. After-sales service
This apparatus has a 12-month warranty since the date of install and inspection.
Beyond the warranty period, company will still provide after-sales service.