Home > Product > Aluminum coil

Contact us

Address:#2411 Buliding Wangding International ,Shangwuwaihuan Road,Zhengzhou City, Henan Province, China
Tel:0086-371-86541330
Mobile:13838103651
Contact Person:Ms lin wang
Fax:0086-371-86541330
Website:https://www.sigma-industry.com/

Aluminum Strip For Transformer

Aluminum Strip For Transformer product name: Aluminum Strip For Transformer
Place of Origin: Peoples Republic of China
Post Date: December 13, 2018
Edit Date: December 13, 2018

Detailed Product Description:

  • Alloy:1100 1060 1350
  • Temper:O
  • MOQ:500kgs
  • Package:Pallet /wooden box
  • Port:Qingdao Tianjin
  • Application:Transfomer
  • Aluminum strip for transformer is used in transformers for electrical engineering and in power distribution, which means in power plants and substations, in local distribution networks, in wind power, industrial plant and the power adaptors belonging to electronic devices.

    Technical Specifications

    ♦Alloy: 1050/1060/1080/1100/1350
    ♦Temper: O H12,H14,H16,H18
    ♦Thickness: 0.2mm–2.0mm
    ♦Width: 50–1200mm
    ♦Packing: Eye to wall and eye to sky, wooden pallet and wooden case
    ♦U. T. S: 60-95N/mm2
    ♦Elongation: >25%
    ♦Max. Resistance in 20 degree: ≤ 0.02825Ω Mm2/m
    ♦Density in 20 degree: 2.703kg/dm3
    ♦Burr’s height: 0.01–0.03mm vary with thickness of the strip
    ♦Collapsed side’s height: 0.05–0.1mm
    ♦Surface: Free of oil,free of scratches

     

    The chemical composition of aluminum strip/foil for transformer winding.

    Table 1
       Unit : weight %
    Si Fe Cu Mn Mg Cr Zn Ti Others Al
    Individual Total
    max.
    0.2
    max.
    0.25
    max.
    0.04
    max.
    0.03
    max.
    0.03
    - max.
    0.04
    max.
    0.03
    max.
    0.03
    - min.
    99.65

    Mechanical properties and electric conductivity of Aluminum Strip/Foil For Transformer.

    Table 2
    Thickness Tensile strength
    N/mm2(MPa)
    Elongation
    %
    Bending 180 buckling inside radius Electric conductivity
    % at 20°C
             
    Over 0.3 to 0.5   Less than 75 25min.   Close contact   62.5min
    Over 0.5 to 0.8   Less than 75 30min.   Close contact   62.5min.
    Over 0.8 to 1.3   Less than 75 35min.   Close contact   62.5min.
    Over 1.3 to 2.0   Less than 75 35min.   Close contact   62.5min.
    Over 2.0 to 2.4   Less than 75 35min.   Close contact   62.5min.

    Typical Application:

    Aluminum Strip for transformer winding can be used for variable transformer like low or high voltage transformer winding, high frequency transformer,step up or down voltage transformer, distribution transformers, reactor and etc. 
  • Tel:0086-371-86541330

    Fax:0086-371-86541330

    Phone:13838103651

    lily@sigma-industry.com